DIN Rail Power Supply Selection: 24V vs 48V Voltage Guide

LRS-100W 100W enclosed switching power supply 12V 24V selectable industrial AC-DC power supply 100W metal case SMPS for LED lighting systems High-efficiency switching power supply for industrial equipment

Introduction: Voltage Selection Fundamentals

DIN rail power supply selection requires careful voltage consideration between 24V systems for traditional industrial control and 48V systems for modern applications. This guide examines voltage options, output configurations, and application-specific recommendations for optimal industrial power system design.


1. Voltage Selection: 24V Industrial Standard

24V Applications and Advantages

Primary 24V Applications encompass most traditional industrial control systems where reliability and safety are paramount.

Sensor Networks:

  • Voltage Requirement: 24V DC standard

  • Application Examples: Proximity sensors, temperature sensors, pressure transducers

  • Advantage: Safe low voltage operation with adequate signal strength

  • Installation Benefit: Standardized across industrial sensor manufacturers

PLC Systems:

  • Power Requirement: 24V DC for CPU and I/O modules

  • Typical Current: 2-10A depending on system size

  • Critical Need: Stable voltage for reliable logic execution

  • Industry Standard: Universal adoption across PLC manufacturers

Relay and Contactor Control:

  • Coil Voltage: 24V DC standard for industrial relays

  • Application: Motor starters, control circuits, safety relays

  • Advantage: Reduced arcing compared to higher voltages

  • Safety Benefit: Lower risk in control cabinet environments

24V Technical Specifications

Performance Characteristics:

  • Safety Classification: SELV (Safety Extra-Low Voltage)

  • Typical Current Range: 1A to 40A available

  • Efficiency: 85-94% in modern switching designs

  • Cable Considerations: Moderate voltage drop concerns

Installation Advantages:

  • Standardization: Universal industrial acceptance

  • Component Availability: Extensive compatible device selection

  • Safety Margin: Reduced shock hazard in maintenance

  • Cost Effectiveness: Competitive component pricing


2. Voltage Selection: 48V Modern Applications

48V Applications and Advantages

Primary 48V Applications address specific requirements where efficiency, distance, or compatibility drive voltage selection.

Communication Equipment:

  • Standard Voltage: 48V DC telecom standard

  • Application Examples: Routers, switches, base station equipment

  • Historical Basis: Traditional telephone system compatibility

  • Modern Usage: Network equipment power redundancy systems

Power over Ethernet (PoE):

  • PoE Standards: 48V for PoE, PoE+, PoE++

  • Maximum Power: Up to 90W with PoE++

  • Application: IP cameras, VoIP phones, wireless access points

  • Advantage: Single cable for data and power

Motor Drives and High-Power Applications:

  • Specific Motors: Some servo and DC brushless motors

  • Advantage: Higher voltage reduces current requirements

  • Efficiency Benefit: Lower I²R losses in windings

  • Application: Certain robotics and precision motion systems

Renewable Energy Systems:

  • Solar Applications: 48V battery bank compatibility

  • Advantage: Efficient power transmission

  • System Integration: Compatible with many charge controllers

  • Expanding Use: Growing in off-grid and hybrid systems

48V Technical Specifications

Performance Characteristics:

  • Efficiency Benefit: Reduced transmission losses

  • Current Reduction: Half the current of equivalent 24V systems

  • Cable Savings: Smaller gauge wiring possible

  • Distance Advantage: Lower voltage drop over long runs

Safety Considerations:

  • Voltage Classification: Still within SELV limits

  • Protection Requirements: Additional considerations needed

  • Installation Practices: Proper insulation and spacing

  • Maintenance Procedures: Enhanced safety protocols


3. Voltage Comparison Matrix

Technical Comparison

 
 
Parameter 24V Systems 48V Systems Selection Guidance
Primary Applications PLCs, sensors, relays Telecom, PoE, network equipment Match existing system standards
Current Requirements Higher current for same power Lower current for same power 48V reduces conductor size
Voltage Drop More significant over distance Less significant over distance 48V for long cable runs
Safety Margin Higher safety factor Requires more precautions 24V for maximum safety
Component Cost Generally lower Some specialized components higher 24V for cost-sensitive projects
Efficiency Good (85-94%) Very good (88-96%) 48V offers slight advantage
System Compatibility Universal industrial standard Specific application standard Follow equipment specifications

Application Decision Guide

Choose 24V When:

  • Controlling PLCs, sensors, or industrial relays

  • Safety is primary concern with frequent human interaction

  • Existing infrastructure uses 24V standards

  • Cable runs are under 50 meters

  • Component cost optimization is critical

Choose 48V When:

  • Powering telecommunications equipment

  • Implementing PoE or PoE+ systems

  • Operating high-power devices efficiently

  • Cable runs exceed 50 meters

  • Integrating with existing 48V infrastructure


4. Output Configuration: Single vs Dual

Single Output Power Supplies

Design Characteristics:

  • Single Voltage Output: Dedicated to one voltage requirement

  • Current Capacity: Full rated current available on single output

  • Simplified Design: Fewer components, potentially higher reliability

  • Cost Efficiency: Typically 15-30% lower cost than dual output equivalents

Optimal Applications:

  • Homogeneous Systems: All devices require same voltage

  • High-Current Needs: Maximum current delivery required

  • Budget-Conscious Projects: Cost-sensitive installations

  • Standard Control Panels: Traditional industrial applications

Example Configurations:

  • 24V/10A Single Output: 240W dedicated to 24V devices

  • 48V/6A Single Output: 288W for telecom equipment

  • 12V/20A Single Output: 240W for specialized applications

Dual Output Power Supplies

Design Characteristics:

  • Multiple Voltages: Typically 12V/24V or 5V/24V combinations

  • Independent Regulation: Each output separately controlled

  • Space Optimization: One unit replaces two single-output supplies

  • System Simplification: Reduced wiring and connections

Common Configurations:

  • 12V/24V Dual Output: For mixed voltage industrial systems

  • 5V/24V Dual Output: For control logic (5V) and power (24V)

  • 24V/48V Dual Output: For hybrid industrial/telecom applications

  • Adjustable Outputs: Some models offer variable voltage settings

Optimal Applications:

  • Mixed Voltage Systems: Different devices require different voltages

  • Compact Control Cabinets: Space-constrained installations

  • Retrofit Projects: Upgrading existing mixed-voltage systems

  • Prototyping Systems: Flexible development and testing environments

Output Configuration Comparison

 
 
Consideration Single Output Dual Output Recommendation
System Flexibility Limited High Dual for mixed voltage needs
Current Availability Full rating on one output Shared between outputs Single for high-current applications
Space Efficiency Standard Excellent Dual for space-constrained cabinets
Cost Efficiency Better per watt Higher functionality cost Single for budget-focused projects
Reliability Potential Simpler design More complex circuitry Single for critical applications
Installation Simplicity Straightforward More connections Single for quick installations
Future Expansion Limited More adaptable Dual for evolving systems

5. Selection Methodology

Step 1: Application Analysis

Voltage Requirements Assessment:

  • Review all connected device specifications

  • Identify primary voltage needs

  • Consider future expansion requirements

  • Evaluate existing infrastructure compatibility

Current Calculations:

  • Sum all device current requirements

  • Add 20-30% safety margin

  • Consider peak vs continuous loads

  • Account for inrush currents

Step 2: Technical Specification Review

Critical Parameters:

  • Input Voltage Range: 85-264VAC for global compatibility

  • Output Regulation: ±1-2% for stable operation

  • Efficiency Rating: 85% minimum, 90%+ preferred

  • Protection Features: OVP, OCP, SCP, OTP

  • Temperature Range: -25°C to +70°C for industrial use

Certification Requirements:

  • Safety Standards: UL 508, IEC 62368-1

  • EMC Compliance: EN 55032, EN 61000

  • Industry Specific: Marine, railway, medical if required

  • Regional Certifications: CE, UKCA, CCC, PSE

Step 3: Environmental Considerations

Operating Conditions:

  • Ambient Temperature: Match to installation environment

  • Altitude Rating: Up to 2000m standard, higher if needed

  • Humidity Levels: 20-90% non-condensing typically

  • Vibration Resistance: Important for industrial machinery

  • Contaminant Protection: IP20 standard, higher if exposed

Installation Environment:

  • Cabinet Type: Enclosed, ventilated, or outdoor

  • Mounting Space: Available DIN rail length

  • Cooling Availability: Natural convection or forced air

  • Access Requirements: Maintenance and service access

Step 4: Economic Evaluation

Cost Analysis Factors:

  • Initial Purchase Price: Unit cost comparison

  • Installation Costs: Wiring, connectors, labor

  • Operating Costs: Energy efficiency impact

  • Maintenance Costs: Expected service requirements

  • Lifecycle Costs: Total cost over expected service life

Value Considerations:

  • Warranty Coverage: 3-5 year typical ranges

  • Technical Support: Availability and quality

  • Delivery Lead Time: Project timeline impact

  • Local Availability: Stock and distribution channels


6. Application Examples

Example 1: Factory Automation Panel

Requirements:

  • Power for: 2 PLCs (5A each), 15 sensors (0.1A each), 8 relays (0.5A each)

  • Voltage: All devices require 24V DC

  • Cabinet: Standard industrial control panel

  • Environment: Manufacturing floor with moderate vibration

Selection:

  • Voltage: 24V (standard for all devices)

  • Configuration: Single output (homogeneous voltage needs)

  • Rating: 24V/20A (480W with 20% margin)

  • Features: DIN rail mount, wide input voltage, OVP/OCP/OTP

Rationale: Single voltage system benefits from simpler single-output design with maximum current availability.

Example 2: Telecommunications Cabinet

Requirements:

  • Power for: PoE switch (48V/4A), router (48V/2A), control system (24V/3A)

  • Cabinet: Wall-mounted telecommunications enclosure

  • Environment: Temperature-controlled indoor location

  • Space: Limited mounting space available

Selection:

  • Voltage: Dual voltage requirement (48V and 24V)

  • Configuration: Dual output or separate supplies

  • Option A: Single 48V/8A supply + 24V/5A supply

  • Option B: Dual output 48V/6A + 24V/4A unit

  • Choice: Option B for space optimization

Rationale: Dual output unit saves space while meeting both voltage requirements in compact cabinet.

Example 3: Mixed Industrial System

Requirements:

  • Devices: PLC (24V/4A), HMI (24V/2A), embedded computer (12V/5A)

  • Cabinet: Modular industrial enclosure

  • Expansion: Planned addition of 24V devices

  • Budget: Moderate with focus on reliability

Selection:

  • Voltage: Mixed (24V and 12V required)

  • Configuration: Dual output 24V/8A + 12V/6A

  • Features: Wide input range, high efficiency, monitoring signals

  • Future: Adequate margin for additional 24V loads

Rationale: Dual output provides both required voltages with expansion capacity for future 24V additions.


7. Installation Best Practices

DIN Rail Mounting

Installation Procedure:

  1. Rail Verification: Confirm TH35-7.5 or TH35-15 compatibility

  2. Position Planning: Allow adequate clearance between units

  3. Mounting Sequence: Install larger/heavier units first

  4. Secure Attachment: Ensure positive clip engagement

  5. Final Check: Verify all units are securely mounted

Clearance Requirements:

  • Vertical Clearance: 10mm minimum above and below

  • Horizontal Spacing: 5mm minimum between units

  • Ventilation Space: Follow manufacturer specifications

  • Access Space: Allow for wiring and maintenance

Wiring Implementation

Input Wiring:

  • Wire Selection: Appropriate gauge for input current

  • Protection Devices: Proper fusing or circuit breakers

  • Grounding: Essential safety ground connection

  • Termination: Secure connections with proper torque

Output Wiring:

  • Voltage Drop Calculation: Ensure adequate conductor size

  • Load Distribution: Balance loads across multiple units if used

  • Connection Method: Screw terminals, spring clamps, or connectors

  • Identification: Clear labeling of all circuits

Thermal Management

Natural Convection Cooling:

  • Orientation: Vertical mounting for optimal airflow

  • Clearance Maintenance: Ensure specified air space

  • Ambient Monitoring: Consider cabinet internal temperature

  • Location: Avoid heat sources within cabinet

Forced Air Considerations:

  • Airflow Direction: Align with unit ventilation pattern

  • Filter Maintenance: Regular cleaning in dusty environments

  • Temperature Monitoring: Cabinet temperature sensors

  • Fan Selection: Appropriate CFM for heat load


8. Troubleshooting Guide

Common Issues and Solutions

Voltage Instability:

  • Symptoms: Fluctuating output, device resets

  • Possible Causes: Input voltage variations, overload conditions

  • Solutions: Verify input power quality, check load within ratings, inspect connections

Overheating Problems:

  • Symptoms: Thermal shutdown, reduced output, hot enclosure

  • Possible Causes: Insufficient ventilation, overload, high ambient temperature

  • Solutions: Improve airflow, verify load, consider derating, monitor temperature

Output Failure:

  • Symptoms: No output voltage, status indicator off

  • Possible Causes: Input power loss, internal fault, protection activated

  • Solutions: Check input power, reset unit if possible, contact manufacturer

Excessive Noise:

  • Symptoms: Audible buzzing, electrical interference

  • Possible Causes: Component vibration, switching frequency, poor filtering

  • Solutions: Secure mounting, check for loose components, verify installation

Preventive Measures

Regular Maintenance:

  • Visual inspection every 6-12 months

  • Connection tightness verification

  • Ventilation clearance maintenance

  • Environmental condition monitoring

Performance Monitoring:

  • Output voltage measurement

  • Temperature monitoring

  • Load current verification

  • Efficiency calculation periodic checks


9. Future Considerations

Technology Trends

Higher Efficiency Standards:

  • Increasing minimum efficiency requirements

  • Improved partial load performance

  • Reduced standby power consumption

  • Advanced thermal management

Smart Features:

  • Communication interfaces (MODBUS, Ethernet)

  • Remote monitoring capabilities

  • Predictive maintenance features

  • Energy usage analytics

Material Advances:

  • Improved thermal interface materials

  • Higher temperature component ratings

  • Reduced size through higher frequency operation

  • Enhanced reliability through better components

Application Evolution

Industrial IoT Integration:

  • Connected power management systems

  • Cloud-based monitoring solutions

  • Automated load balancing

  • Predictive failure analysis

Energy Management:

  • Peak load management capabilities

  • Renewable energy integration

  • Energy storage compatibility

  • Smart grid interaction

Safety Enhancements:

  • Advanced protection algorithms

  • Arc fault detection

  • Ground fault monitoring

  • Enhanced isolation capabilities


Conclusion: Optimal Selection Strategy

DIN rail power supply selection balances voltage requirements, output configuration, technical specifications, and application needs. The choice between 24V and 48V systems depends primarily on connected equipment, while single vs dual output selection hinges on system complexity and space constraints.

Final Recommendations:

Voltage Selection Summary:

  1. Choose 24V for: PLCs, sensors, relays, general industrial control

  2. Choose 48V for: Telecom equipment, PoE systems, specific motor drives

  3. Consider both when: Mixed systems or future expansion anticipated

Output Configuration Summary:

  1. Select single output for: Homogeneous voltage systems, high-current needs

  2. Select dual output for: Mixed voltage applications, space optimization

  3. Evaluate carefully when: Cost sensitivity vs functionality balance needed

Implementation Priority:

  1. Match equipment requirements precisely

  2. Include adequate safety margins for reliability

  3. Consider future expansion during initial selection

  4. Verify all certifications for compliance needs

  5. Plan installation carefully for optimal performance

Long-Term Success Factors:

  • Proper sizing with adequate margins

  • Quality components from reputable manufacturers

  • Correct installation following best practices

  • Regular maintenance and monitoring

  • Documentation and training for personnel


Technical Support: Contact power system specialists for assistance with DIN rail power supply selection specific to your application requirements. Professional guidance ensures optimal performance, reliability, and compliance with industry standards and regulations.